Cobham plc
 
 
 
 

Frequently Asked Questions


Coastal Series Questions

Are there any procedures for setting up a Series 98 or Coastal Series antenna on Sky Mexico?

04 Series Questions

Is there any special Sea Tel equipment needed to view HDTV?
  • Yes, the HDTV Converter Kit (P/N 123575), is required to view HDTV for DirecTV on the 110 W satellite. I & O Procedure
Are there any Installation procedures for the Dual Antenna Arbitrator Assembly?
  • Yes, refer to the 124238-2 (2 Coax Switch) or the 124238-4 (4 Coax Switch) Procedures.
What information is needed when trying to isolate a series 04-pedestal failure?
  • To make a full evaluation, we need the following information along with a full failure analysis for any xx03/04 Installations:
    1. Compass type (GPS, Flux Gate, Gyro, None)
      To help determine Satellite Reference or Gyro Reference mode
    2. Auto Threshold setting
      Calculate the Difference between Peak AGC and Noise Floor AGC. AUTO THRES should be set to 1/3 to ½ of the Difference.
    3. Gyro Type setting
      Determined by Compass type
    4. System Type setting
      Reference section 5 in the DAC2000 manual for setting options
    5. On satellite AGC reading
      Peak on Satellite AGC reading, Tracking on, NID decoded or Video produced on TV
    6. Off satellite AGC reading
      Drive antenna elevation 10 to 15 degrees above targeted position
    7. Remote Monitor response to Remote Command of "S0000" (For xx03 system, use decimal 83 to get "S0000" command)
      Use Comm diagnostics (under tools tab) on DacRemP to get Remote Monitor Response
      You can download the latest version of DacRemP on the Diagnostic Tools page
      Use "?S" command and record response
      Reference Command Codes section on diagnostic information page to decode remote monitor response.
      Reference section 7 Troubleshooting and Maintenance section of the Series 04 manual for keystroke help on DAC2200

    8. In some cases, the following may be required:
    9. El Step Size
      Sets Elevation Conscan sensitivity or the Step Track trial movement size. Series 04 factory default for is 0
    10. AZ Step Size
      Sets azimuth Conscan sensitivity or the Step Track trial movement size. Series 04 factory default is 0
    11. Step Integral
      Sets the integration time for Tracking Mode. Series 04 factory default is 0
    12. Search Delay
      Sets the time-out for automatic initiation of a search after the signal level drops below threshold. Units are in seconds. Range is 0-255 seconds. 0000 disables the automatic search feature
    Please provide us with settings above and we can give you an accurate determination of the problem.