We offer a standard product line of Aluminium, Copper or brass pressure windows designed from different flanges standards.
The high temperature dielectric window allows very high electrical performances and moderate CW power.
High power pressure windows with Quartz material and specific vacuum tests products are available upon request.
| Reference | Waveguide | Frequency (GHz) | VSWR Nominal | Pressure (Kg/Cm2) | Peak power (kW) |
| FP 284 | WR 284 | 2,60 - 3,95 | 1,06 | 1,05 | 2000 |
| FP 229 | WR 229 | 3,30 - 4,90 | 1,07 | 1,40 | 1800 |
| FP 187 | WR 187 | 3,95 - 5,85 | 1,06 | 1,75 | 1500 |
| FP 159 | WR 159 | 4,90 - 7,05 | 1,05 | 2,10 | 1000 |
| FP 137 | WR 137 | 5,85 - 8,20 | 1,07 | 2,45 | 750 |
| FP 112 | WR 112 | 7,05 - 10,0 | 1,10 | 2,80 | 500 |
| FP 102 | WR 102 | 7,00 - 11,0 | 1,10 | 3,00 | 350 |
| FP 90 | WR 90 | 8,20 - 12,4 | 1,10 | 3,15 | 300 |
| FP 75 | WR 75 | 10,0 - 15,0 | 1,10 | 3,15 | 200 |
| FP 62 | WR 62 | 12,4 - 18,0 | 1,10 | 3,50 | 150 |
| FP 51 | WR 51 | 15,0 - 22,0 | 1,10 | 3,85 | 100 |
| FP 42 | WR 42 | 18,0 - 26,5 | 1,12 | 4,20 | 75 |
| FP 34 | WR 34 | 22,0 - 33,0 | 1,15 | 4,55 | 60 |
| FP 28 | WR 28 | 26,5 - 40,0 | 1,18 | 4,90 | 45 |