L band | Available frequency band (MHz) | Bandwidth | Isolation | Insertion loss | VSWR |
| 1500-1700 | <10 % | 23dB | 0.2 dB | 23 dB |
S/C band | Available frequency band (MHz) | Bandwidth | Isolation | Insertion loss | VSWR |
| 3000-7000 | <15 % | 23dB | 0.2dB | 23 dB |
X band | Available frequency band (MHz) | Bandwidth | Isolation | Insertion loss | VSWR |
| 7000-10000<10 % | 21dB | 0.25 dB | 21 dB | |
Ku band | Available frequency band (Mhz) | Bandwidth | Isolation | Insertion loss | VSWR |
| 11000-18000 | <7 % | 23dB | 0.25 dB | 21 dB |
These performances should be read in operating temperature range
Maximum ratings | | Min | Max |
| Operating temperature range | -20 °C | + 70 °C |
| Storage operating temperature range | -40 °C | +85 +C |
Environnemental conditions
Vibration condition : according ESA/SCC 3202 requirements The components shall be subjected to test ‘Fc’ of IEC Publication N°.68-2-6, sweep frequency 10-2000- 10 Hz. The entire frequency range of 10 to 2000 Hz and return to 10 Hz shall be traversed in 10 minutes.
This constitutes one cycle. The vibration amplitude shall be 1.5 mm from 10 Hz to the higher cross-over frequency and then 20 g acceleration to 2000 Hz
- Frequency band